Grid-Tied Inverter Sizing Calculator

Grid-tie inverters are normally sized a little smaller than the solar array. Enter your array size and target DC/AC ratio to find the right inverter and see how much energy clipping would cost in your climate.

THELOADCALCIN-06 · Inverters unit
Inverter sizeIN-06
7.6kW AC
Exact target6.67kW
Actual DC/AC ratio1.05
Est. clipping loss0.0%
Good match for this climate
Solar array size
Target DC/AC ratio
1.20
Climate

How the grid-tied inverter sizing calculation works

Inverter kW = Array kWp ÷ DC/AC ratio
Rounded up to the next standard inverter size
  • Ratios of 1.15–1.3 are standard. In cool, cloudy climates panels rarely reach full output, so higher ratios lose almost nothing.
  • In hot, sunny climates panels hit peak power more often, so clipping starts at lower ratios.
  • Standard residential sizes include 3.8, 5, 6, 7.6, 10 and 11.4 kW.

Frequently asked questions

What size inverter do I need for an 8kW solar system?

+

At a 1.2 DC/AC ratio, about 6.7 kW, so a 7.6 kW inverter is the nearest standard size.

What is the best DC/AC ratio?

+

Usually 1.15–1.3. It lowers cost per kWh by keeping the inverter busy, with only small clipping losses.

Should I oversize my inverter for future panels?

+

Only if you definitely plan to add panels soon. Otherwise a slightly undersized inverter is cheaper and more efficient.

Results are engineering estimates for planning. Confirm final designs against equipment datasheets and local electrical codes, and have high-voltage or grid-connected work checked by a licensed electrician.