How the battery bank sizing calculation works
- Days of autonomy is how long the bank must last with no solar input: 1–2 days for grid backup, 3–5 days for off-grid homes.
- The 0.9 factor covers inverter and wiring losses between the battery and your appliances.
- Cold batteries deliver less capacity, so the bank is enlarged when the coldest battery temperature is below 25°C.
Frequently asked questions
How big a battery bank do I need for off-grid?
+
Using 5 kWh per day with 2 days of autonomy and 80% depth of discharge needs about 14 kWh of batteries, or roughly 290Ah at 48V.
How many days of autonomy should I plan for?
+
Two to three days is typical for off-grid homes with a backup generator. Plan for five or more without a generator in cloudy climates.
Should I use 12V, 24V or 48V?
+
Use 12V for small systems under about 1.5 kW, 24V up to around 3 kW, and 48V for anything larger. Higher voltage means lower current and thinner cables.
Results are engineering estimates for planning. Confirm final designs against equipment datasheets and local electrical codes, and have high-voltage or grid-connected work checked by a licensed electrician.