How the hybrid solar system sizing calculation works
Array kW = Daily kWh × Solar share ÷ (Sun hours × 0.82)
Battery kWh = Critical W × Backup hours ÷ 1000 ÷ 0.81
Inverter ≥ max(Critical × 1.25, Array ÷ 1.3)
- Solar share is the percentage of your yearly use you want solar to supply. 60–80% is typical without oversizing.
- Battery size is driven by critical loads during an outage (fridge, lights, internet, medical devices), not by your whole house.
- Grid import covers whatever solar does not, so a hybrid system never runs out of power while the grid is up.
Frequently asked questions
What size battery do I need for a hybrid system?
+
Enough to run critical loads through a typical outage. 1.5 kW of critical load for 12 hours needs about 22 kWh.
Is a hybrid system better than grid-tied?
+
It costs more, but keeps your essentials running during outages and lets you use more of your own solar where export rates are low.
How much solar does a 20 kWh/day home need?
+
To cover 70% with 4.5 sun hours, about 3.8 kW of panels.
Results are engineering estimates for planning. Confirm final designs against equipment datasheets and local electrical codes, and have high-voltage or grid-connected work checked by a licensed electrician.