How the cable length vs efficiency loss calculation works
- Cable loss grows with the square of current, so halving the current cuts loss to a quarter.
- That is why doubling system voltage for the same power reduces cable loss by 75%.
- Losses above 2–3% are usually worth fixing with thicker cable or a shorter run.
Frequently asked questions
How much power is lost in a long DC cable?
+
Carrying 2,000W at 24V over 10 m of 6 AWG copper loses about 180W, or 9%. At 48V the loss drops to about 2.2%.
Is it better to put the inverter near the batteries?
+
Yes. Keep the high-current DC run between batteries and inverter as short as possible, and run the lower-current AC output the longer distance.
Does cable loss affect solar panel wiring?
+
Less so, because panel strings run at high voltage and low current. Loss matters most on low-voltage battery cables.
Results are engineering estimates for planning. Confirm final designs against equipment datasheets and local electrical codes, and have high-voltage or grid-connected work checked by a licensed electrician.